Megger Sverker900 Standard
The Megger SVERKER 900 Relay and Substation Test System is the engineer’s ultimate toolbox that addresses the increasing need for three-phase testing capability in electrical distribution substations, renewable power generation stations and industrial applications. The Sverker 900 is the ideal instrument for use in applications that include commissioning and maintenance of distribution substations and generator installations; testing of electromechanical, static and numerical protection relays; plotting current transformer excitation curves; burden measurement for CTs; polarity/direction measurement; impedance measurement; single and three-phase injection testing in switchgear; checking SCADA annunciation and measurement values; and performing network measurements. To complement the current and voltage generators, the SVERKER900 features a large colour touchscreen that provides an intuitive user interface and a powerful internal processor that eliminates the need to use an external computer for most types of manual and semi-automatic testing. Full manual control and configuration is also supported and, in addition to the touchscreen, the instrument is provided with a large rotary knob that can be configured as required to control the current and voltage generators. Test configurations and test results are stored in internal non-volatile memory and can be readily transferred to and from a PC via the instrument’s USB port. The intuitive user interface is presented on the LCD touch screen. It has a powerful combination of current and voltage sources and a versatility of measurement possibilities. FEATURES The toolbox for substation 3-phase testing. Three currents and four voltages. Stand-alone functionality. Rugged and reliable for field use. Generation of 900 V and 105 A in single phase mode. Secondary and primary testing. SVERKER900 Relay and Substation Test System Video Megger Sverker900 Specifications Specifications are valid for resistive load, at 170-240 voltage supply and ambient temperature +25°C +3°C (77°F +5.4°F) after 30 minutes warmup time and in the frequency range of 10 Hz to 70 Hz. All hardware data are for full scale values. Specifications are subject to change without notice. Environment Application Field For use in high-voltage substations and industrial environments. Operating Temperature 0 to 50°C (32 to +122°F). Storage/Transport Temperature -40 to +70°C (-40 to +158°F). Humidiity 5 to 95% RH, non-condensing. Altitude (Operational) 2000m (6500ft). Shock and Vibration IEC 60068-2-27. Vibration IEC 60068-2-6. CE-Marking EMC IEC61326-1. LVD IEC61010-1: 2010. General Specification Mains Input 100 to 240V AC, 50/60 Hz. Current Consumption 10 A (max). Power Consumption 1800 VA (max). Instrument Dimensions 350 x 270 x 220 mm (13.8 x 10.6 x 8.7"). Flight Case with Wheels 615 x 295 x 500 mm (24.2 x 11.6 x 19.7"). Flight Case 620 x 295 x 500 mm (24.4 x 11.6 x 14.4"). Weight 14.9 kg (32.8lbs) - instrument only. 29.0 kg (64lbs) with accessories and flight case (with wheels, GD-00185). 23.9 kg (52.7lbs) with accessories and flight case (GD-00182). Display 5.7" LCD touch screen. Available Languages English, French, German, Spanish and Swedish. Measurement Section Binary Inputs 1,2, 3, 4 and EXTERNAL TIMER Start/Stop Number 6. Type Dry or wet contacts max, 240V AC or 340V DC. Galvanic Isolation 35 minutes. Max Measuring Time Settable, 0 to 999 ms. BINARY INPUT 1 Settable, 0 to 999 ms. Timer Range Inaccuracy 0 to 50ms ?1ms. 50 to 500ms ?2ms. >500ms ?1%. Resolution 1ms. Voltmeter Measurement Method AC true RMS DC mean value. Insulation 900 V, 1273 peak. Input Rating 900 V. Inaccuracy (DC Ranges) 0 to 1V +0.5% of reading + 3 mV. 0 to 10V +0.5% of reading + 7 mV. 0 to 100V +0.5% of reading + 30 mV. 0 to 900V +0.5% of reading + 300 mV. Inaccuracy (AC Ranges) 0 to 1V +1% of reading + 5 mV. 0 to 10V +1% of reading + 10 mV. 0 to 100V +1% of reading + 50 mV. 0 to 900V +1% of reading + 300 mV. Resolution 1 mV. Frequency Range 10 Hz to 600 Hz. Inaccuracy <0.01%. Resolution >10 mHz. Ammeter Measurement Method AC true RMS DC mean value. Inaccuracy (Ranges DC) 0 to 200mA +0.5% of reading + 2 mA. 0 to 1.5A +0.5% of reading + 3 mA. 0 to 10A +0.5% of reading + 10 mA. Inaccuracy (Ranges AC) 0 to 200mA +1% of reading + 2 mA. 0 to 1.5A +1% of reading + 3 mA. 0 to 10A +1% of reading + 20 mA. Frequency Range 10 Hz to 600 Hz. Inaccuracy <0.01%. Resolution <10 mHz. Extra Measurements Power Factor Range 0.01 (cap) to 1 to +0.01 (ind). Resolution <0.01. Inaccuracy <0.04. Phase Angle (°) Range 0 to 360°. Resolution <0.1°. Inaccuracy <0.8°. Impedance and Power Measurement AC Z(Ω), R(Ω),X (Ω), P(W), S(VA), Q(VAR). DC R(Ω), P(W). Range Up to 999kX (X = unit). Binary Outputs Insulation 250V AC. Current 1 A (max). Voltage 250V AC. Generation Section Voltage outputs U1, U2, U3 and U4/DC out. All voltage sources/generators are galvanically separated from each other and from ground. Floating common return is made by using jumper connectors. Ranges 4-Phase AC 4 x 300 V. 4-Channel DC 4 x 300 V. Power 4-Phase AC 4 x 125 VA (max). 4-Channel DC 4 x 125 W (max). Inaccuracy 0.03% range + 0.05% of reading). Distortion (THD + N) <0.14% typical (0.25% max). Resolution 10 mV. Phase Angle Range 0 to 360°. Inaccuracy <0.5° (at 50-60 Hz). Resolution 0.1°. Frequency Range 10 Hz to 600 Hz. Inaccuracy <0.03% (45 to 66 Hz). Resolution 1 mHz.

For more information on Megger Sverker900 Standard talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title