NB: The Megger TXL830 (BS-59003) is supplied without accessories.
The Megger TXL830 load unit is designed for use together with TORKEL battery load units. Their purpose is to provide higher load currents for use in constant current or constant power tests. Together, TORKEL and the TXL extra loads form a system that can discharge batteries with currents of up to several kA. TXL extra loads are connected directly to the battery, and TORKEL measures the total current using a clamp-on ammeter.
The Torkel TXL830 extra load unit is shut down automatically when TORKEL is stopped.
Megger TXL830, 850, 870, 890 Specifications
AC/DC Voltage
Voltage DC Max
Current Max
Power Max
TXL830
28 V
300 A
8.3 kW
TXL850
56 V
300 A
16.4 kW
TXL870
280 V
112 A
15.8 kW
TXL890
480 V
62 A
15.4 kW
Internal Resistance, 3-Position Selector
Position 1
Position 2
Position 3
TXL830
0.275 Ω
0.318 Ω
0.092 Ω
TXL850
0.55 Ω
0.275 Ω
0.184 Ω
TXL870
4.95 Ω
2.48 Ω
1.24 Ω
TXL890
14.10 Ω
7.05 Ω
3.52 Ω
Maximal Currents, 3 Position Selector
Position 1
Current
Voltage
Cells
Cell Voltage
TXL830
100 A
27.6 V
12
2.3 V
78.5 A
21.6 V
12
1.8 V
TXL850
100 A
55.2 V
24
2.3 V
78.5 A
43.2 V
24
1.8 V
TXL870
50.1 A
248.4 V
108
2.3 V
39.2 A
194.4 V
108
1.8 V
TXL890
32.3 A
469.2 V
204
2.3 V
26.0 A
367.2 V
204
1.8 V
Position 2
Current
Voltage
Cells
Cell Voltage
TXL830
200 A
27.6 V
12
2.3 V
156 A
21.6 V
12
1.8 V
TXL850
200 A
55.2 V
24
2.3 V
156 A
43.2 V
24
1.8 V
TXL870
50.1 A
124.2 V
54
2.3 V
39.2 A
97.2 V
54
1.8 V
TXL890
35.2 A
248.4 V
108
2.3 V
27.8 A
194.4 V
108
1.8 V
Position 3
Current
Voltage
Cells
Cell Voltage
TXL830
300 A
27.6 V
12
2.3 V
235 A
21.6 V
12
1.8 V
TXL850
300 A
55.2 V
24
2.3 V
235 A
43.2 V
24
1.8 V
TXL870
100 A
124.2 V
54
2.3 V
74.8 A
97.2 V
54
1.8 V
TXL890
70.5 A
248.4 V
108
2.3 V
55.2 A
194.4 V
108
1.8 V
Environment
The instrument is intended for use in high voltage substations and industrial environments.
Operating temperature
0°C to +40°C (32°F to +104°F).
Storage temperature
-40°C to +70°C (-40°F to +158°F).
CE Marking
LVD: IEC61010-1:2010
EMC: IEC61326 -1.
Main Voltage
100 - 240 V AC, 50 / 60 Hz.
Power consumption
75 W (max).
Protection
Thermal cut-outs, automatic overload protection.
Dimensions
Instrument: 210 x 353 x 600 mm (8.3” x 13.9” x 23.6”)
Transport case: 265 x 460 x 750 mm (10.4” x 18.1” x 29.5”).
Weight
13 kg (29 lbs) 21.4 kg (47 lbs) with transport case.
Storage temperature
-40°C to +70°C (-40°F to +158°F).