Find The Needle Add My Company
Megger TXL870 Utility Load Unit
NB: The Megger TXL870 Utility (BS-59007) is supplied without accessories. The Megger TXL870 load unit is designed for use together with TORKEL battery testers. Their purpose is to provide higher load currents for use in constant current or constant power tests. Together, TORKEL and the TXL extra loads form a system that can discharge batteries with currents of up to several kA. TXL extra loads are connected directly to the battery, and TORKEL measures the total current using a clamp-on ammeter. The Torkel TXL870 extra load unit is shut down automatically when TORKEL is stopped. Megger TXL830, 850, 870, 890 Specifications AC/DC Voltage Voltage DC Max Current Max Power Max TXL830 28 V 300 A 8.3 kW TXL850 56 V 300 A 16.4 kW TXL870 280 V 112 A 15.8 kW TXL890 480 V 62 A 15.4 kW Internal Resistance, 3-Position Selector Position 1 Position 2 Position 3 TXL830 0.275 Ω 0.318 Ω 0.092 Ω TXL850 0.55 Ω 0.275 Ω 0.184 Ω TXL870 4.95 Ω 2.48 Ω 1.24 Ω TXL890 14.10 Ω 7.05 Ω 3.52 Ω Maximal Currents, 3 Position Selector Position 1 Current Voltage Cells Cell Voltage TXL830 100 A 27.6 V 12 2.3 V 78.5 A 21.6 V 12 1.8 V TXL850 100 A 55.2 V 24 2.3 V 78.5 A 43.2 V 24 1.8 V TXL870 50.1 A 248.4 V 108 2.3 V 39.2 A 194.4 V 108 1.8 V TXL890 32.3 A 469.2 V 204 2.3 V 26.0 A 367.2 V 204 1.8 V Position 2 Current Voltage Cells Cell Voltage TXL830 200 A 27.6 V 12 2.3 V 156 A 21.6 V 12 1.8 V TXL850 200 A 55.2 V 24 2.3 V 156 A 43.2 V 24 1.8 V TXL870 50.1 A 124.2 V 54 2.3 V 39.2 A 97.2 V 54 1.8 V TXL890 35.2 A 248.4 V 108 2.3 V 27.8 A 194.4 V 108 1.8 V Position 3 Current Voltage Cells Cell Voltage TXL830 300 A 27.6 V 12 2.3 V 235 A 21.6 V 12 1.8 V TXL850 300 A 55.2 V 24 2.3 V 235 A 43.2 V 24 1.8 V TXL870 100 A 124.2 V 54 2.3 V 74.8 A 97.2 V 54 1.8 V TXL890 70.5 A 248.4 V 108 2.3 V 55.2 A 194.4 V 108 1.8 V Environment The instrument is intended for use in high voltage substations and industrial environments. Operating temperature 0°C to +40°C (32°F to +104°F). Storage temperature -40°C to +70°C (-40°F to +158°F). CE Marking LVD: IEC61010-1:2010 EMC: IEC61326 -1. Main Voltage 100 - 240 V AC, 50 / 60 Hz. Power consumption 75 W (max). Protection Thermal cut-outs, automatic overload protection. Dimensions Instrument: 210 x 353 x 600 mm (8.3” x 13.9” x 23.6”) Transport case: 265 x 460 x 750 mm (10.4” x 18.1” x 29.5”). Weight 13 kg (29 lbs) 21.4 kg (47 lbs) with transport case. Storage temperature -40°C to +70°C (-40°F to +158°F).

For more information on Megger TXL870 Utility Load Unit talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title