Sign In
The MI 3121 SMARTEC Insulation / Continuity is a new generation tester for dead testing of electrical installations. With both an analogue and digital representation of the results, the instrument ensures accurate measurements up to 2000 Ω on continuity and up to 30 GΩ on insulation function.
Configurable limits enable a PASS / FAIL evaluation of test results, which is accompanied with the bright red and green indicator lights for comfortable use even in the dark conditions. The MI 3121 is equipped with a built-in charger and has a magnetic holder in order to free up hands for testing.
FEATURES
Large LCD display with bargraph and backlight.
High measuring range of up to 30 GΩ with test voltage from 50 V to 1000 V.
Fast and reliable continuity tests with automatic polarity reversal.
Voltage and frequency measurements.
Pre-programmed limits.
PASS/FAIL evaluation of measurement result.
Bright GREEN/RED indicators provides visual evaluation of results.
Suited for testing on CAT IV installations.
Magnetic holder allowes hands-free operation.
Built-in battery charger.
Two level memory structure for saving of test results and parameters.
Basic downloading with EuroLink PRO PC SW package.
Compatible with EuroLink PRO Plus PC SW package.
USB and RS232 ports.
Metrel MI3121 SMARTEC Insulation & Continuity Tester (2.5kV) Technical Specifications
Insulation Resistance
Insulation resistance (test voltages 100 VDC and 250 VDC)
Measuring range according to EN 61557 is 0.15 MΩ ... 999.9 MΩ.
Measuring Range
Resolution (MΩ)
Accuracy
0.00 ... 19.99
0.01
+(5 % of reading + 3 digits)
20.0 ... 199.9
0.1
+10 % of reading
200 ... 999
1
+20 % of reading
Insulation resistance (test voltages 500 VDC, 1000 VDC)
Measuring range according to EN61557 is 0.15 MΩ ... 30 GΩ.
0.00 MΩ ... 19.99 MΩ
0.01
+(5 % of reading + 3 digits)
20.0 MΩ ... 199.9 MΩ
0.1
+5 % of reading
200 MΩ ... 299 MΩ
1
+5 % of reading
300 GΩ ... 999 GΩ
1
+5 % of reading
1.00 GΩ ... 4.99 GΩ
10
+10 % of reading
5.00 GΩ ... 19.9 GΩ
10
+20 % of reading
20.0 GΩ ... 29.9 GΩ
100
indicative.
Continuity (200 mA)
Measuring range according to EN61557 is 0.16 Ω ... 1999 Ω
Measuring range (Ω)
Resolution (Ω)
Accuracy
0.00 ... 19.99
0.1
+(5 % of reading + 3 digits)
200 ... 1999
1
+(5 % of reading + 3 digits)
Open-circuit voltage
6.5 VDC ... 9 VDC.
Measuring current
min. 200 mA into load resistance of 2 Ω.
Test lead compensation
up to 5 Ω.
Automatic polarity reversal of the test voltage.
Continuity (7 mA)
Measuring range (Ω)
Resolution (Ω)
Accuracy
0.0 ... 19.9
0.1
+(5 % of reading + 3 digits)
20 ... 1999
1
+(5 % of reading + 3 digits)
Open-circuit voltage
6.5 VDC ... 9 VDC.
Short-circuit current
max. 8.5 mA.
Test lead compensation
up to 5 Ω.
Voltage
Measuring range (V)
Resolution (V)
Accuracy
0.00 ... 9.99
0.01
+(3 % of reading + 3 digits)
10.0 ... 99.9
0.1
+(5 % of reading + 3 digits)
100 ... 550
1
+(5 % of reading + 3 digits)
Result type
True r.m.s. (TRMS)
Nominal frequency range
0 Hz, 15 Hz ... 500 Hz.
Frequency
Measuring range (Hz)
Resolution (Hz)
Accuracy
0.00 ... 19.99
0.01
+(0.2 % of reading + 1 digit)
20.0 ... 199.9
0.1
+(0.2 % of reading + 1 digit)
200 ... 500
1
+(0.2 % of reading + 1 digit)
Nominal voltage range
10 V ... 550 V.
General Data
Power supply
6 x 1.5 V batteries or rechargeable batteries, size AA.
Overvoltage category
CAT III / 600 V; CAT IV / 300 V.
Protection classification
double insulation.
Pollution degree
2.
Protection degree
IP 40.
Display
custom liquid crystal display with backlight.
Memory
1900 measurements.
Dimensions (w x h x d
14 cm x 8 cm x 23 cm.
Weight (without batteries)
0.8 kg.
For more information on Metrel MI 3121 SMARTEC Insulation Continuity Tester talk to Cuthbertson Laird Group
Enquire Now
List your company on FindTheNeedle.