Sign In
Metrel MI 3125BT COMBO plus the METREL A 1532 Electric Vehicle Adaptor
The A 1532 EVSE (Electric Vehicle Supply Equipment) adapter is a special accessory intended for testing Electric Vehicle Supply Equipment (EVSE) together with supported METREL installation testers. The A 1532 is intended for testing Mode 3 EV supply equipment with a type 2 connector.
To choose the MI 3125BT COMBO + A 1532 Adpt please select the option in the dropdown above the price.
The A 1532 is supported with the Metrel MI 3125BT COMBO.
The Metrel MI 3125BT is the ideal instrument for engineers who perform high volume testing or work regularly on TT and TN systems. Containing all necessary tests for installation safety testing, MI 3125BT offers the brand new ability to test B-type (DC sensitive) RCDs. COMBO contains integrated characteristics of fuses and RCDs (including EV type) for the evaluation of line/loop impedance results.
The bright graphic display with backlight ensures that results, indications, measurement parameters and messages are clear, visible and easy to read. The red and green LEDs on either side of the display provide a clear PASS/FAIL evaluation of test results. Each test has its own individual help screen describing how to connect the instrument into the installation and how to perform a measurement.
MEASURING FUNCTIONS
Insulation resistance with DC voltage.
Continuity of PE conductors with 200 mA test current with polarity change.
Continuity of PE conductors with 7 mA test current (continuous measurement) without RCD tripping.
Line impedance.
Loop impedance.
Loop impedance with Trip Lock RCD function.
TRMS voltage and frequency.
Phase sequence.
RCD testing (general and selective, type AC, A and B).
Earth resistance (3-wire method).
Metrel MI 3125BT COMBO Specifications
Function
Measuring Range
Resolution
Accuracy
Insulation resistance (EN 61557-2)
U = 50, 100, 250 VDC:
R: 0.00 MΩ ... 19.99 MΩ
0.01 MΩ
+(5 % of reading + 3 digits)
20.0 MΩ ... 99.9 MΩ
0.1 MΩ
+10 % of reading.
100.0 MΩ ... 199.9 MΩ
0.1 MΩ
+20 % of reading.
U = 500 VDC, 1 kVDC.
R: 0.00 MΩ ... 19.99 MΩ
0.01 MΩ
+(5 % of reading + 3 digits).
20.0 MΩ ... 99.9 MΩ
0.1 MΩ
+5 % of reading.
200 MΩ ... 999 MΩ
1 MΩ
+10 % of reading.
Continuity 200 mA of PE conductor with polarity change (EN 61557-4)
0.00 Ω ... 19.99 Ω
0.01 Ω
+(3 % of reading + 3 digits).
20.0 Ω ... 199.9 Ω
0.1 Ω
+5 % of reading.
200 Ω ... 1999 Ω
1 Ω
+5 % of reading
Loop impedance (EN 61557-3)
0.00 Ω ... 9.99 Ω
0.01 Ω
+(5 % of reading + 5 digits)
10.0 Ω ... 99.9 Ω
0.1 Ω
+(5 % of reading + 5 digits)
100 Ω ... 999 Ω
1 Ω
+10 % of reading
1.00 kΩ ... 9.99 kΩ
10 Ω
+10 % of reading
Line impedance (EN 61557-3)
0.00 Ω ... 9.99 Ω
0.01 Ω
+(5 % of reading + 5 digits)
10.0 Ω ... 99.9 Ω
0.1 Ω
+(5 % of reading + 5 digits
100 Ω ... 999 Ω
1 Ω
+10 % of reading
1.00 kΩ ... 9.99 kΩ
10 Ω
+10 % of reading
Voltage
0 V ... 550 V
1 V
+(2 % of reading + 2 digits)
Frequency
0.00 Hz ... 9.99 Hz
0.01 Hz
+(0.2 % of reading + 1 digits)
10.0 Hz ... 499.9 Hz
0.1 Hz
Phase sequence (EN 61557-7)
1.2.3 or 3.2.1.
RCD testing (EN 61557-6)
?N: 10 mA, 30 mA, 100 mA, 300 mA, 500 mA, 1 A.
Contact voltage UC
0.0 V ... 19.9 V
0.1 V
(-0% / +15%) of reading +10 d.
20.0 V ... 99.9 V
0.1 V
-0% / +15%) of reading.
Trip-out time
0 ms ... 40.0 ms
0.1 ms
+1 ms.
0 ms ... max. time
0.1 ms
+3 ms.
Trip-out current
0.2 x I?N ... 1.1 x I?N (AC type)
0.05 x I?N
+0.1 x I?N.
0.2 x I?N ... 2.2 x I?N (A type,?N < 30 mA)
0.05 x I?N
+0.1 x I?N.
0.2 x I?N ... 1.5 x I?N (A type, I?N ? 30 mA)
0.05 x I?N
+0.1 x I?N.
0.2 x I?N ... 2.2 x I?N (B type)
0.05 x I?N
+0.1 x I?N.
Earth resistance (EN 61557-5)
0.00 Ω ... 19.99 Ω
0.01 Ω
+(5 % of reading + 5 digits).
20.0 Ω ... 199.9 Ω
0.1 Ω
+(5 % of reading + 5 digits).
200 Ω ... 9999 Ω
1 Ω
+(5 % of reading + 5 digits).
General Specifications
Power supply
6 x 1.5 V alcaline or 6 x 1.2 V rechargeable batteries, size AA.
Overvoltage category
600 V / CAT III; 300 V / CAT IV.
Protection class
double insulation.
COM port
RS232 and USB.
Dimensions
140 x 80 x 230 mm.
Weight
1.0 kg.
Metrel A1532 Electric Vehicle Charger Tester Technical Specifications
Input voltage
400 V (3-phase).
Frequency
50 Hz.
Test current
13 A.
Proximity Pilot (PP) simulation
Open circuit
13 A
20 A
32 A
63 A
Control Pilot (CP) simulation
State A (not connected)
State B (connected, not charging)
State C (charging without ventilation)
State D (charging with ventilation)
State E (error - CP short to PE via diode)
Overvoltage category
300 V CAT II.
Protection degree
IP 40.
Pollution degree
2.
Protection classification
Double insulation.
Altitude
3000 m above sea level.
Dimensions (L x W x H)
200 x 100 x 70 mm.
Test lead length
0.5 m.
Weight
0.82 kg.
Working temperature range
0 °C . 40 °C @ 95 % RH, non-condensing
Storage temperature range
-10 °C . +70 °C.
Maximum storage relative humidity
90 % RH (-10 °C . +40 °C)
80 % RH (40 °C . 60 °C).
For more information on Metrel MI 3125BT COMBO Multifunction Tester talk to Cuthbertson Laird Group
Enquire Now
List your company on FindTheNeedle.