Find The Needle Add My Company
Metrohm E3640 4kV AC Flash Tester
The Metrohm E3640 is an AC flash tester for leakage and breakdown testing. It is designed for voltage testing of electrical apparatus, components and insulating materials. The E3640 is housed in a rugged, moulded plastic case with integral carrying handle. The hinged detachable lid is fitted with a pouch which contains all accessories and the instruction manual. All operating functions are mounted on a panel underneath the protective lid. The twin 3 1/2 digit LCD displays show both output voltage and leakage current. FEATURES 115V and 230V operation. 50/60Hz frequency selection. Applies up to 4kV AC. Displays output voltage and leakage current. Twin 3.5 digit LCD screens. Breakdown mode when fast transients can trigger tripping. Burn mode where the trip function is bypassed and the fault current flows continuously to expose the faulty. Hold function shows full breakdown of voltage and leakage current. Mains powered. Metrohm E3640 Specifications Electrical Power Requirement 115/230 V +15% 50/60 Hz 40 VA. Fuses 230 V - 5x20 mm 0.25 A, HBC, Type F 115 V - 5x20 mm 0.5 A, HBC, Type F. Output Voltage Range 0 - 2.2, 0 - 4.2 kV 50/60 Hz. Output Voltage Accuracy + 2% of reading + 1 digit. Leakage Current 0 - 5 mA (nominal) 50/60 Hz in 10 µA steps. Leakage Current Accuracy +2% of reading + 1 digit. Trip Level Range 0 to 3 mA 50/60 Hz. Setting Accuracy +5% of full range. Trip Response Leakage Will trip for fault duration >5 mS but not for <100 µS. Breakdown Will trip for fast transients of 30 µS and above. Mechanical Weight 4 kg. Dimensions 330 x 263 x 144 mm. Bump Test IEC 68-2-29. Vibration, Impact and Drop BS EN61010 8.3, 8.2, 8.4. Environmental Operating Temperature -15°C to +55°C. Storage Temperature -25°C to +65°C. Operating Humidity 80% RH at 40°C. Installation Category II BS EN 61010 - Annex J. Pollution Degree 2 BS EN 61010 - clause 3.7.3.2. Indicators kV ON Red lamp shows the high voltage circuit is energised. FAIL A red lamp which indicates the trip has triggered. Audible Fail A buzzer indicates the trip has triggered. Controls Power Switch Type Double pole ON/OFF rocker type. Mode Select Three position rotary switch selects the breakdown, trip or burn mode of operation. Trip Level Single turn trip level setting potentiometer. Voltage Select Two position rotary switch for 2 or 4 kV range. Voltage Control Single-turn potentiometer for accurate setting of the output voltage. Connectors Power Inlet A module which combines a filter with an IEC 320 inlet with an ON/OFF double pole rocker. Low/Earth Terminal Large yellow/green binding post. High Voltage Outlet Red custom designed deep socket. Leads / Probes Earth Lead A green heavy duty flexible lead with a 4mm plug and a fixed shrouded crocodile clip at the other. High Voltage Probes A custom moulded pistol shaped probe with a trigger operated retractable “hot” end. A red high voltage lead emerges from the bottom of the hand grip and is terminated with especially designed high voltage safety connector. EMC To BS EN 50081-1 and BS EN 50082-2. Safety and Flash Test To BS EN 61010-1. Metrohm E3640 warranty One-year.

For more information on Metrohm E3640 4kV AC Flash Tester talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title