Sign In
The Clare Sentinel 501 electrical safety tester (manufactured by Seaward) enables manufacturers to check their products in-house to ensure compliance with the relevant international technical conformance standards. Significant time and cost saving benefits are provided by the Sentinel 501 bench-top Hipot/flash tester from Clare, which deliver improved type testing during product development or enhanced compliance testing in a laboratory environment.
A remote start terminal and signal I/O port allows for remote starting, safety interlocking and PLC control while an enhanced safety feature will automatically cut off the output voltage within 150?s where normal output voltages are detected or when the upper or lower current trip limits are reached while the device is under test.
The Sentinel series is ideal for R&D facilities and compliance laboratories, while design, quality assurance, and manufacturing and production engineers will also benefit from the easy-to-use safety test features.
SENTINEL SERIES KEY FEATURES
500 VA capability (Sentinel 500 series).
Earth bond / insulation resistance (Sentinel 501).
Sweep function for test analysis.
Flexible / high resolution test parameters .
Manual / automatic test modes.
Remote and PLC control.
Fast cut off and automatic discharge.
Seaward Sentinel Series Comparison Chart
Features
200
500
501
Earth/ground Bond
AC dielectric strength - 5 kV
DC dielectric strength - 6 kV
DC insulation resistance
200 VA (40 mA)
500 VA (100 mA)
ARC detection
Seaward Sentinel 501 Specifications
AC Dielectric Strength
Programmable Voltage Range
0.100 kV - 5.000 kV (2V/Step Resolution).
Frequency Independent of Supply
50 or 60 Hz Selectable.
Output Voltage Accuracy
+1% + 5 Volts (No Load).
Voltage Display Resolution
0.001 kV.
Current Measurement
0.001 mA - 100.0 mA.
Range and Accuracy
+1.5% + 30 Counts when trip limit <1.11mA
+1.5% + 3 Counts when trip limit >1.11mA.
Current Display Resolution
0.001 mA / 0.001 mA / 0.1 mA.
Selectable Range of Pass/Fail Levels
0.001 mA - 100.00 mA.
Maximum Rated Current
100 mA (0.5 kV ? V ? 5 kV)
10 mA (0.1 kV ? V ? 0.5 kV).
Arc Detection
Yes.
Ramp time
0.1 - 999.9s.
Test Time
Off / 0.5s - 999.9s.
DC Dielectric Strength
Programmable Voltage Range
0.100 kV - 6.000 kV
(2V/Step Resolution).
Frequency Independent 50 or 60 Hz Selectable of Supply
50 or 60 Hz Selectable.
Output Voltage Accuracy
+1% + 5 Volts (No Load).
Voltage Display Resolution
0.001 kV.
Current Measurement
0.001 mA - 20.0 mA.
Range and Accuracy
+1.5% + 30 Counts when trip limit <1.11 mA
+1.5% + 3 Counts when trip limit >1.11 mA.
Current Display Resolution
0.001 mA / 0.001 mA / 0.1 mA.
Selectable Range of Pass/Fail Levels
0.001 mA - 20.00 mA.
Maximum Rated Current
20 mA (0.5 kV ? V ? 5 kV)
2 mA (0.1 kV ? V ? 0.5 kV).
Arc Detection
Yes.
Ramp time
0.1 - 999.9s.
Test Time
Off / 0.5s - 999.9s.
Earth Bond
Programmable Test Current
03.00 A - 32.00 A ac.
Test Current Resolution
0.01 A.
Test Current Accuracy
3 A - 8 A: (1% of rdg+0.2 A)
8 A - 32 A: (1% of rdg+0.05 A).
Test Voltage
6 V AC max (open circuit).
Test Voltage Frequency
50 Hz/60 Hz selectable.
Resistance Measurement Range
10mΩ - 650.0 mΩ.
Resistance Measurement Resolution
0.1 mΩ.
Resistance Measurement Accuracy
(1% of rdg + 2 mΩ).
Test Time
0.5 - 999.9s.
Arc Detection
Yes.
Insulation Resistance
Output Voltage
50 V - 1000 V.
Output-Voltage Resolution
50 V / Step.
Output-Voltage Accuracy
+(1% of setting +5 V)[no load].
Resistance Measurement Range
0.001 GΩ -50.00 GΩ.
Test Voltage
50 V - 450 V
0.001 - 0.050 GΩ
0.001 - 0.500 GΩ.
500 V - 1000 V
0.051 - 2.000 GΩ
0.501 - 9.999 GΩ
10.00 - 50.00 GΩ.
Selectable Range of Pass/Fail Levels
0.001 mA - 20.00 mA.
Output Impedance
Yes.
RAMP (Ramp-Up Time)
600 kΩ.
TIMER (Test Time)
1s~999.9s.
General Specifications
Dimensions
330W x 148H x 587D mm.
Weight
Approx 27 kg.
Sentinel 501 warranty
1 year (subject to product registration with Seaward).
For more information on Seaward Sentinel 501 Electrical Safety Tester talk to Cuthbertson Laird Group
Enquire Now