The Testo 310 Flue Gas Analyser combines simple functions with a high level of measurement accuracy, and is perfect for all basic measurements on heating systems. Long battery lifetimes of up to 10 hours guarantee high availability. It’s easy handling and compact design make the Testo 310 a robust tool for daily work - even when things get rough.
The Testo 310 stands out thanks to its easy handling and menu-guided security. You can read off the measurement values confidently and conveniently from the well-lit display, even in bad light conditions. The fuels are stored not just as numbers, but are each described. At the top edge of the clear display, the symbols for the different measurement menus are always in view.
FEATURES
Robust and light instrument for daily use.
30 seconds sensor zeroing.
Integrated condensate trap.
Integrated magnets for easy fixing to burner.
Testo 310 Product Video
Testo 310 Specifications
Temperature - TC Type K (NiCr-Ni)
Measuring range
-20 to +100 °C.
Accuracy
+1 °C.
Resolution
0.1 °C.
Reaction time
< 50 s.
Temperature - TC Type J (Fe-CuNi)
Measuring range
0 to +400 °C.
Accuracy
+1 °C (0 to +100 °C)
+1.5 % of mv (> 100 °C).
Resolution
0.1 °C.
Reaction time
< 50 s.
Flue gas O?
Measuring range
0 to 21 Vol.%.
Accuracy
+0.2 Vol.%.<
Resolution
0.1 Vol.%.
Reaction time t??
30 s.
Flue Gas Draught
Measuring range
-20 to +20 hPa.
Accuracy
+0.03 hPa (-3.00 to +3.00 hPa)
+1.5 % of mv (Remaining Range).
Resolution
0.01 hPa.
Flue Gas Degree Of Effectivity, Eta (calculated)
Measuring range
0 to 120 %.
Resolution
0.1 %.
Flue Gas Loss (calculated)
Measuring range
0 to 99.9 %.
Resolution
0.1 %.
Flue gas CO? Calculation (calculated from O?)
Measuring range
0 to CO? max (Display range).
Accuracy
+0.2 Vol.%.
Resolution
0.1 Vol.%.
Reaction time t??
< 40 s.
Pressure Measurement
Measuring range
-40 to +40 hPa.
Accuracy
+0.5 hPa.
Resolution
0.1 hPa.
Flue gas CO (without H?-compensation)
Measuring range
0 to 4000 ppm.
Accuracy
+20 ppm (0 to 400 ppm)
+5 % of mv (401 to 2000 ppm)
+10 % of mv (2001 to 4000 ppm).
Resolution
1 ppm.
Reaction time t??
60 s.
Ambient CO
Measuring range
0 to 4000 ppm.
Accuracy
+20 ppm (0 to 400 ppm)
+5 % of mv (401 to 2000 ppm)
+10 % of mv (2001 to 4000 ppm).
Resolution
1 ppm.
Reaction time
60 s.
General Technical Data
Dimensions
201 x 83 x 44 mm.
Operating temperature
-5 to +45 °C.
Display type
LCD.
Display function
Backlit 2-line display.
Power supply
Battery: 1500 mAh, mains unit 5V/1A.
Storage temperature
-20 to +50 °C.
Weight
(with probe) Approx. 700 g.
Testo 310 warranty
2 years.