Sign In
Whether it`s for carrying out checks on flanges, fittings or any other places that are typically prone to leaking, the Testo 316-2 gas leak detector provides you with a speedy and sure means of detecting higher concentrations of methane, propane and hydrogen in the surrounding air.
Even if you already know that a pipe is leaking, you normally still have a long way to go before you can actually locate the leak. The testo 316-2 gas leak detector is just the right tool for carrying out such pinpointing detection. The detector`s easy-to-read 18-step bar display and maximum leakage reading show the concentration of combustible gas in the surrounding air and lead you quickly and reliably to the source of the leak. The detector also has an audible alarm that warns you when a threshold is crossed and a headphone jack which allows you to connect earphones for more focused and productive working in loud or distracting environments.
The testo 316-2 is extremely user-friendly and ideally suited to fast check measurements thanks to its integrated pump, its optical presentation of the gas concentrations detected, and the integrated rechargeable battery.
FEATURES
Optical and audible alarm with bar display for increasingand dangerous gas concentrations.
Trend display shows maximum leakage.
Integrated pump.
Flexible measurement probe for inaccessible places.
Earphone connection for secure leakage localisation inloud surroundings.
High duration of use thanks to rechargeable battery.
Testo 316-2 Specifications
General Technical Data
Operating humidity
20 to 80 %RH.
Weight
348 g.
Reaction time
t?? < 2 s.
Dimensions
190 x 57 x 42 mm (without sensors).
Operating temperature
-5 to +50 °C.
Heat up time
60 s.
Battery type
NiMH battery.
Battery life
6 h.
Display type
18 segment bar display.
Storage temperature
-25 to +60 °C.
Methane (CH?)
Measuring range
10 ppm to 4.0 Vol.%.
Lower response threshold
10 ppm.
1st alarm limit
200 ppm.
2nd alarm limit
10000 ppm.
Propane (C?H?)
Measuring range
10 ppm to 1.9 Vol.%.
Lower response threshold
10 ppm.
1st alarm limit
100 ppm.
2nd alarm limit
5000 ppm.
Leak Detection H?
Measuring range
10 ppm to 4.0 Vol.%.
Lower response threshold
10 ppm.
1st alarm limit
200 ppm.
2nd alarm limit
10000 ppm.
For more information on Testo 316-2 Multi Gas Leak Detector talk to Cuthbertson Laird Group