Sign In
ADS Outalarm® with Capacitance Probe
Product Code: A100C96A
Applications
Specifically designed for liquid terminal operation on batch loading and overfill protection, tank cars, tank trucks, marine barges, suitable for open and close dome
Specifications
Intrinsically safe design per ANSI/UL913 Class I, Div I Groups A, B, C and D Hazardous Areas
Features
Totally self-contained; no wires, tubing or external power
Rugged weather and corrosion resistant construction
No moving parts, tip sensitive phase shift™ digital capacitance sensor for conductive and non-conductive fluid
Requires no calibration or adjustment
Operates up to 2500 hours on a single 9V alkaline battery
Adjustable insertion length through a standard 1/2" NPT fitting
High intensity audible and flashing visual outputs
Full, hard graduated laser engraved rod
Fail safe continuous battery monitor goes to alarm state on low battery
Activation point 1/4" above liquid surface
Battery current drain <0.23 ma during standby; <50 ma in alarm state
Horn intensity 101 dB at 2'
Light output 3 each 3000 mcd high intensity flashing LED's
Capacitance Phase Shift Probe
1/2 NPT gland standard
Minimum dielectric constant 1.8
For more information on ADS Outalarm® with Capacitance Probe talk to Dixon Group Europe Ltd
Enquire Now
List your company on FindTheNeedle.