Sign In
Burnley Hospital have had major roofing problems with old building
stock. The old bitumen felt roofs on the Family Care Unit had very
little thermal value and large areas of blistered and split asphalt,
allowing water in to the building, flooding patient wards and
damaging expensive, sensitive equipment.
Gables carried out a survey of the roof areas, took core samples and
offered a warm roof overlay solution to bring the roof up to current
building regulations. The building had to remain occupied
throughout the contract.
Stone chippings were removed at weekends and works were
programmed around patient care, in particular, the replacement of
the roof lights with new triple skin units. Gables installed 120mm PIR
insulation over the prepared roof deck and a new carrier membrane
before applying the Tor Coatings Elastaseal 20 system.
All works were completed on time and within budget without any
patient disruption.