AC Voltage Transducers
DescriptionDIN rail mounting transducers available in 55mm x 112mm or 100 x 112mm DIN ?rail casesApplicationUsed to conver various inputs into standard DC signals for driving panel meters and for use in control devices. Selection GuideM100-VA11ph. self powered ave. sensing RMS calibratedM100-VL11ph. aux powered ave. sensing RMS calibratedM100-VR11ph. aux powered true RMS sensing RMS cal.M100-VA33ph. self powered ave. sensing RMS calibratedM100-VL33ph. aux powered ave sensing RMS calibratedTypical ApplicationsThe M100 series voltage transducers are designed to measure AC voltage in single and 3 phase systems. They convert the A.C. signal to a D.C. output that is directly proportional to the input signal. The M100-VA1, VA3 are self powered (ie no auxiliary required) average sensing RMS calibrated voltage transducers, mA and voltage outputs are available.The M100-VR1 is true RMS sensing RMS calibrated allowing measurement of distorted waveforms of up to 9th harmonic with a crest factor of 5. The VR1 is typically used in voltage measurements where distorted waveforms are common such as in thyristor drives. The above units are used to measure voltage in energy management systems, switchboards, generator and telemetary controls. Isolation of 4kV is provided between the input and output signal, allowing the output to be fed to conventional analogue meters, digital meters, PLC, and computer systems.Technical SpecificationsINPUTRated value Un:57.8 < 100 / 110 < 600VPower Consumption< 1.5VA (VA1, VA3)<1VA(VL1,VL3,VR1)Working Range:15-125% Un(VA1,VA3)0-125%Un(VL1,VL3,VR1)Rated Frequency:50 / 60 / 400HzFrequency influence:0.005% / HzOverload continuous:1.5 x UnOverload for 1 sec:4 x Un (VL1,VL3,VR1) 2 x Un(VA1,VA3)OUTPUTRated value mA0-1 / 5 / 10 / 20mA (VA1, VA3)Rated value mA1 / 5 / 10 / 20 & 4-20mA (VR1)Rated value mA4-20mA (VL1, VL3)Rated value volts0-5 / 10V (VA1,VA3)Rated value volts0-5 / 10 & 1-5V (VR1)Rated value volts1-5V (VL1, VL3)ADJUSTMENTZero:No adjustment (VA1, VA3)Zero:± 2% (VR1, VL1)Span:± 10% (VA1,VA3,VR1,VL1,VL3)AUXILIARYA.C. Voltage115 / 230 / 400V(± 25% / 45-65Hz / < 2VAD.C. Voltage(24 / 48 / 110V±20% / galvanically isolated / <3W)WEIGHT&CASE SIZEM100-VA1Approx 0.3 kg. 55mm caseM100-VL1,VR1Approx 0.4 kg. 55mm caseM100-VA3Approx 0.6 kg 100mm caseM100-VL3Approx 0.7 kg. 100mm caseOrdering InformationProduct CodeInput InOutputAuxFreqOptionsM100-AL15A4-20mA230V50HzOptions1Non standard inputs/outputs as far as technically viable2A.C. Auxiliary in range 57.7 to 450 volts3Calibration at nominal Hz 35-450Hz4Calibration at temperature other than 23CA.C. Current Connection Diagrams

For more information on AC Voltage Transducers talk to Howard Butler Ltd

Enquire Now

  Please wait...

Location for : Listing Title