Sign In
DescriptionDIN rail mounting protection relays for use in single and three phase systems. Available in 55mm x 112mm or 100 x 112mm DIN rail casesApplicationFor over protection, under protection and combined under & over protection available in AC current AC voltage & frequency versions. Millivolt trip, DC voltage trip, Reverse Power, Phase sequence & Phase balance relays also available in our extensive range of protection relays..Selection GuideM200-F1USingle or 3 phase under frequencyM200-F1OSingle or 3 phase over frequencyM200-F1CSingle or 3 phase combined frequency?Typical ApplicationsThe M200 series frequency protection relays are designed to monitor the frequency of a system and if the frequency deviates outside the customer adjustable preset limits, the relay will operate. Typically used in protecting generators against under or over speed, this is achieved as speed is proportional to frequency.Other uses such as monitoring mains power supplies, computer supplies etc. The user is provided with adjustment of both the trip point of frequency being monitored and the differential. As is common with all the M200 relays, on over units the relay energises when the input signal exceeds the trip point. A red LED indicates the state of the relay, whilst a green LED indicates the condition of the power supply. The frequency relays monitor their own power supply so no auxiliary power is required.?Technical SpecificationINPUTRated value Un57.8<500V ±25%Rated frequency50/60/400HzBurden< 2.5VAOverload1.5 x Un continuous 2 x Un for 3 secondsSETPOINTRange 50Hz nominalAdjustable 40 to 60HzRange 60Hz nominalAdjustable 50 to 70HzRange 400HzAdjustable 360 to 440HzDifferential 50 & 60HzAdjustable 0.3 to 3HzDifferential 400HzAdjustable 3 to 30HzRepeatabilityBetter than 0.5% of full spanOperating TimeTypically 200msAUXILIARYAll units self poweredWEIGHT&CASESingle unitsApprox 0.4kg. 55mm caseCombined UnitsApprox 0.6kg. 100mm caseOptions1On all of the above units an internally set time delay is available for any value between 1 & 10 seconds. To order use the above codes adding a D at the end of the code. e.g M200-F1U / D7 seconds (state the fixed delay period).2AC auxiliary in range 57.7 to 480 volts3To prevent nuisance tripping when there is a slight variation in the frequency the following option is available. The external differential is replaced with an external time delay. On these units the time delay is adjustable from 200mS to 10 second, and the differential is fixed at 1%.M200-F1X: Single or 3 phase under frequencyM200-F1Y: Single or 3 phase over frequencyM200-F1W: Single or 3 phase combined frequency4Calibration at temperature other than 23CConnection Diagrams
For more information on Frequency Protection Relay talk to Howard Butler Ltd
Enquire Now
List your company on FindTheNeedle.