Find The Needle Add My Company
M560 Powersig Transducers
DescriptionDIN Rail mounting multifunction transducers supplied in 100 x 112mm DIN rail cases.The M560 PowerSig is a complete 1 phase or 3 phase multifunction AC power transducer with 3 analogue outputsApplicationSelf contained measurement of a wide range of electrical paremeters, where comunication options are requiredAnalogue OutputsUpto 3 fully isolated outputs are available. Most of the parameters measured can be assigned to the outputs. Outputs can be either DC mA or DC volts. If PowerSig is purchased without the option of RS485 the user must specify which parameter is required for each output when ordering.OptionsRS485 Output ? This is auto configurable and set up software is provided.Pulsed Output ? This can be assigned to Wh, Varh, Ah or VahModelDetailsM560-AT1: Single PhaseM560-AT1-3:Single Phase 3 wireM560-AT4: 3 Phase 3 wire Unbalanced LoadM560-AT9: 3 Phase 4 wire Unbalanced LoadDC AuxiliaryIf RS485 output is not required. The customer should specify which parameter is required for analogue outputs, CT ratios, VT ratios, pulse duration etc. These can be programmed by out factory before despatch.Ordering InformationInformation RequiredExampleProduct CodeM560-AT9Nominal Input Voltage230 / 400V ACNominal Input Current5A ACSystem Frequency50HzAuxiliary230VOutput3 x 4-20mAOptionRS485 ModbusSpecificationsACCURACYINPUTSpecified @ 23C 10%-Un 10%-lnRated Un: Direct connected voltages between 57.8 and 600V. Specify NominalParemeters unless stated: Class 0.3% to IEC 688Range: 2-120% UnVolts and Amps: Class 0.25% to IEC 688Overload 1.5 x Un cont. 4 x Un for 1 secFrequency: Class: 0.1Hz o IEC 688Rated In: 1 or 5 AmpPower Factor: Class: 1.0% to IEC 688Range 2-120% InActive and Reactive Energy: 1% of reading IEC 1036Burden: 0.5VA per phase Volts & AmpsOverload: 4 x In continous. 50 x In for 1 secFrequency 50/60Hz Nominal range 45/65HzANALOGUE OUTPUTSAPPLIED STANDARDS3 Outputs: Programmable to any 3 parameters (Apart from energy measurements)General: IEC688 BSEN60688, BS4889, IEC359.Rated value: Specified @ 20mAEMC:0-1mA into < 10 kOhm loadEmmisions: BSEN50081/10-5mA into < 2 kOhm loadImmunity BSEN50082/20-10mA into < 1 kOhm loadSafety: IEC 1010, BSEN6010100-20mA into < 0.5 kOhm load4-20mA into < 0.5 kOhm load0-10 volts > 1 kOhm loadINSULATIONTest voltage:4kV RMS 50 Hz for 1 minInputs / Case / Auxiliary / Output3kV RS485 / Outputs1.5kV relay1kV between OutputsImpulse Test:EMC 5kV transient coplies with IEC801/ EN55020 HFSurge Withstand:IEC801/EN55020 Ansi C37.90AInterference:EHF 2.5kV 1Mhz complying to IEC255-4Protective class II:Complying to IEC348ENVIRONMENTAPPROVALSWorking temp: 0 ? +60CUL C-UL CSAStorage temp: -30 ? 65CTemp coefficient: 0.01% per CAUXILIARYAC voltage 115 or 230 or 277 volts (± 15%)DC voltage 12 / 24 / 48 / 110 / 125 volts (± 15%)Case DimensionsConnection Diagrams

For more information on M560 Powersig Transducers talk to Howard Butler Ltd

Enquire Now

  Please wait...

Location for : Listing Title