Find The Needle Add My Company
Phase Balance Protection Relay
DescriptionDIN rail mounting protection relays for use in single and three phase systems. Available in 55mm x 112mm or 100 x 112mm DIN rail cases.ApplicationFor over protection, under protection and combined under & over protection available in AC current AC voltage & frequency versions. Millivolt trip, DC voltage trip, Reverse Power, Phase sequence & Phase balance relays also available in our extensive range of protection relays.Selection GuideM200-PB1Detects phase loss & phase unbalanceM200-PB2Detects phase loss, phase imbalance & symmetrical undervoltageTypical ApplicationsThe M200-PB1 can detect the following conditions in 3 phase 3 or 4 wire systems. Phase unbalance, Phase loss, Phase Reversal, Phase Sequence. The phase balance relays are used to detect phase loss and unbalance in systems using motors, generators, heater elements, transformers etc. A phase unbalance as small as 10% in a 3 phase motor can cause the temperature in the motor winding to increase by more than 120%, correct setting of the PB1/PB2 will ensure that this does not occur. Protection against open phase regenerated voltage created if a single phase should fail is also provided. Customer adjustment of unbalanced voltage between 5 to 15% is provided along with time delay adjustment of 200mS to 10 seconds. If the system being monitored is healthy, the relay is energised, red LED illuminated, if there is a phase unbalance greater than the preset level or phase loss/reversal occurs, the relay de-energises after the time delay period. The M200-PB2 provides all the protection features of the PB1 with the additional benefit of having symmetrical under voltage protection. This means that if all 3 phase voltages remain balanced, but drop below a preset voltage, the relay will de-energise. The under voltage is internally set, for standard units it is set at 85% below the nominal voltage but this value can optionally be between 70 and 90%.Technical SpecificationsINPUTRated value Un57.8 < 500V ±25%Frequency50 / 60 / 400HzBurden<2VAOverload1.5 x Un 2 x UnSETPOINTRangeAdjustment 5% to 15% unbalanced voltageRepeatabilityBetter than 0.5% of full span.UndervoltagePB2 only, preset 85% of nominal voltage(optional 90% to 70%)Time delayAdjustable 200ms to 10 secondsAUXILIARYSelf poweredWEIGHT&CASEApprox 0.4kg. 55mm caseOrdering InformationProduct CodeUn InputFreqOptionM200-PB2415V50HzUnder volts at 70%Options1Adjustable time delay max 30 seconds2Internal under voltage set between 90% and 70%3Calibration at nominal Hz 35-450Hz4Calibration at temperature other than 23CConnection Diagrams

For more information on Phase Balance Protection Relay talk to Howard Butler Ltd

Enquire Now

  Please wait...

Location for : Listing Title