Find The Needle Add My Company
Testec TT-SI-9010A Active Differential Probe High Voltage 70MHz, 700V / 7000V
Looking for more info about Testec TT-SI-9010A Active Differential Probe High Voltage 70MHz, 700V / 7000V?

Testec Active Differential Probe High Voltage 70MHz, 700V / 7000V / 5000Vrms Features: Bandwidth: 70MHz Attenuation: x100 / x1000 Accuracy: ±2% Input impedance: 50 MΩ, 10 pF Measurement Category: CAT III Rise Time: 5 nS Connect only to grounded measuring devices Input Voltage: Differential Mode: x100 ±700 V (DC + peak AC) or 500 Vrmsx1000 ±7000 V (DC + peak AC) or 5000 Vrms Common mode: x100 ±7000 V (DC + peak AC) or 5000 Vrmsx1000 ±7000 V (DC + peak AC) or 5000 Vrms Absolute max. Voltage: x100 ±7000 V (DC + peak AC) or 5000 Vrms x1000 ±7000 V (DC + peak AC) or 5000 Vrms Output voltage Max amplitude: ±1.4 V (into 50kΩ load) Offset: <+-5mV Noise voltage (typical): 0.9 mVrms Source impedance (typical): 50 Ω CMRR (typical): -80 dB @ 50 Hz, -60 dB @ 20 kHz Additional Specification: Power requirements: 4x AA Cells or Mains Adaptor6 VDC / 200 mA or reguliert 9 VDC / 120 mA Dimensions (L x W x H): 202 mm x 83 mm x 38 mm    

Please contact us for more information about Testec TT-SI-9010A Active Differential Probe High Voltage 70MHz, 700V / 7000V.

For more information on Testec TT-SI-9010A Active Differential Probe High Voltage 70MHz, 700V / 7000V talk to Warwick Test Supplies Ltd