The PMC I/O Module 846-506/516 is a member of
Intellitec's Programmable Multiplex Control family. It
works in combination with the PMC CPU and other
standard, semi-custom, or custom I/O modules.
The 506/516 provides power-fusing, switching, and
distribution in one module. With it's six, solid-state, highside
outputs it is capable of controlling a total of 37 Amps.
The outputs are controlled by field effect
transistors and are ideal for high use applications; such as
flashing warning lights, turn signals and brake lights.
There are four input connections for rocker, limit, or
sensor switches. Each individual input can be configured
as either a low-side switch to ground, or a high-side switch
to battery. Input informatioN is directly communicated to
the CPU via the PMC communications link. All of the
input/output harnesses are connected withAMP Mate-NLok
connectors to reduce installation time and errors.
Please refer to the tables in this brochure for proper load
distribution.
This module should be installed in a protected
environment inside a vehicle.
DIRECTCONNECTOUTPUTS5AND6
Direct Connection between inputs 7 and 8 and outputs 5
and 6 can be accomplished by setting dip switch 5 and 6
to the on position. When set for direct connect, the
respective output will turn on within 1ms of receiving an
input at 7 or 8. The purpose of the direct connect outputs
is to eliminate the delay caused by communication with
the CPU. This setting bypasses any boolean that may be
written for these channels. Inputs at 7 and 8 may be High
or Low side inputs.
DIAGNOSTICSANDLED INDICATORS
Next to each output connection you will find a green LED. If
the output is on, the LED will illuminate. If a fuse is blown
and the output should be on, the LED will not illuminate.
A Red LED Illuminates when power is applied. When
multiplex communications are present and correct, theCOM
LED will Illuminate.
If the module's circuit board exceeds 100 C, all outputs will
turn off protecting the module. The COM LED will flash
indicating that an over temperature condition exists. After
cool down, and after power is removed and reapplied the
module will return to normal function. The module will record
the number of times overheating has occurred and upon
initial power up the LED will flash the number of times the
module has been overheated.