The customer required a chamber to cover the temperature range -20°C to +150°C in order to test electronic assemblies. Occasionally, the test was to involve a temperature dwell at -20°C when the components could dissipate up to 1750 watts, and due to this the chamber was fitted with an uprated cooling system. An additional cable port was fitted to enable the items under test to be powered up, and the trolley was fitted with antistatic castors. The floor of the test area had to be at a specific height as stated by the customer, and furthermore the weight of the test item meant the chamber floor would have to be reinforced. The chamber was fitted with an over temperature safety system to ensure the test product never reached a temperature that would cause it any damage.