Combination wave generator is fully programmable up to 24kV/12kA. Short circuit test rig provides up to 1500A phase synchronous short circuit currents on the single phase supply in accordance with clause 7.7.3, 7.7.4 and 7.7.5 The SPD test lab at Cranage is the only facility in the UK that is equipped to fully test Class 3 SPD?s to the following specifications:- • EN61643-11:2002 +A11 (Aug 2007) Surge protective devices connected to low-voltage power systems • EN61643-21:2001 Surge protective devices connected to telecommunications and signaling networks The short circuit test rig was designed and developed by Cranage to meet the new A11 test requirements for Class 3 SPD?s. Reliability and accuracy of measurement is vital in providing a quality service and Cranage technical personnel have both the skills and experience to ensure that these two factors are maintained to the highest standards possible. In-house training ensures that all personnel are kept up-to-date with the latest standards as they emerge.